Page 7-46 Section 7 – Adjustment, Repair, and Replacement CFP83 Series Water Temperature Gauge Removal/Installation (Cont) Install Position the gauge in the panel. Orient it for ease of reading. Position the meter bracket on the gauge’s mounting studs. Start the nuts. Tighten the nuts hand tight plus a full turn. Connect the two dark blue [METER +] wires on the [I] terminal on the gauge. Connect the single black ground wire on the [G] terminal on the gauge. Connect the single [WTG] wire on the [S] terminal on the gauge. Raise the control panel and install the panel mounting bolt. Follow-Up Reconnect the batteries and any battery chargers.
Observe that the [WATER TEMP] gauge indicates a reasonable value for cooling water temperature. If the gauge does not indicate correctly, refer to Troubleshooting Section 12. If the gauge does indicate correctly, place the AUTO/MANUAL Switch at the local panel in the MANUAL position. Drawing No. 9777, Section 7, Rev. 02-07