Section 7 – Adjustment, Repair, and Replacement Page 7-181 CFP83 Series Turbocharger Wastegate Actuator Removal and Installation (Cont) Test NOTE: In some applications, the turbocharger must be removed in order to test the wastegate actuator. Refer to Procedure 010-033. Disconnect the integral boost line from the wastegate capsule. Attach a dial indicator (1) as shown, so that its shaft is in line with the wastegate actuator rod. Set the indicator to zero. Connect clean, regulated air pressure and a pressure gauge to the capsule. Apply 200 kPa [29 psi] to make sure the wastegate is functioning properly.
The rod should move approximately 0.33 to 1.27 mm [0.013 to 0.050 in] without any sticking or air leakage. NOTE: No air should be heard (i.e., leaking noise) through a functional wastegate capsule. NOTE: A small amount of travel when air pressure is first applied is normal; the tolerance is being removed from the system. Replace the actuator if no movement of the actuator rod and lever is detected. Drawing No. 9777, Section 7, Rev. 02-07