Page 12-8 Section 12 – Troubleshooting CFP83 Series Voltage Indications Differ NOTE: The two voltmeters may differ slightly due to calibration differences between the meters. Normal differences in battery condition may also cause differences in indication. These are normal differences and require no action. A voltage difference of more than three or four volts should be investigated. Drawing No. 9777, Section 12, Rev. 02-07 Cause Correction One battery is discharged or failing. Check battery condition. Replace failing battery elements. Check wiring for corrosion. Ensure good electrical contact. Charge discharged batteries by running the engine or with an external battery charger.
If the battery does not charge with the engine running, go to Only One Battery is Charging with the Engine Running. Fuse 1 or Fuse 2 is open. Check for apparent wire damage or shorts to grounds. Refer to Drawing 10423 Sheet 1 in Section 13. Correct any electrical faults. Replace the failed fuse. If the fuse operates again, locate and correct the overload or repair the short circuit. Open circuit or short to ground in indicator wiring. Locate and repair the electrical fault. Refer to Drawing 10423 Sheet 1 in Section 13. Voltmeter has failed. Remove wiring at the voltmeter and apply test voltage. If necessary, replace the faulted voltmeter. Refer to Voltmeter Removal/Installation in Section 7.
Contact an Authorized Cummins Repair Facility.