Page 12-68 Section 12 – Troubleshooting CFP83 Series Engine Will Not Reach Rated Speed (RPM) (Cont) Drawing No. 9777, Section 12, Rev. 02-07 Cause Correction Tachometer is malfunctioning. Replace the tachometer. Refer to Tachometer Removal/Installation in Section 7. Engine power output is low. Refer to the Engine Acceleration or Response Poor symptom tree in this section. Fuel grade is not correct for the application, or the fuel quality is poor. Operate the engine with the required fuel. Refer to Fuel Recommendations and Specifications in Section 10. Fuel filter is clogged. Replace the fuel filter. Refer to Change Fuel Filter in Section 5. Fuel suction line is restricted.

Check the fuel suction line for restriction. Charge air cooler air flow is restricted (CFP83-F40 Only). Inspect the charge air cooler for internal and external restrictions. Replace the restricted cooler if necessary. Refer to Charge Air Cooler (CAC) Removal and Installation in Section 7. Aftercooler air flow is restricted (CFP83-F10, F20, F30 Only). Inspect the aftercooler for internal and external restrictions. Replace the aftercooler if necessary. Refer to Aftercooler Assembly (010-002) in Troubleshooting and Repair Manual C Series Engines, Bulletin Number 3666003-02. Calibrate the fuel pump.