Operating Instructions - Section 30 OM3063 Page 30-18 3. Remove the plug and install the necessary QD return fittings listed in Table 2 into the QD Return port on the bleeddown manifold. 3. Connect the return hose to the return disconnect coupling (2). 4. Start the engine on the good truck. Check the operation of the steering and brake system of the good truck before moving the disabled truck. 5. To disconnect the hoses, stop the engine(s) on both trucks. Wait two minutes for the hydraulic systems on both trucks to bleed down. Ensure all hydraulic pressure has been relieved before disconnecting the hoses. 4. The supply jumper hose must be equipped with quick disconnect fitting PB4682.
This will connect to quick disconnect fitting (1). 5. The return jumper hose must be equipped with fitting PB4684 to connect with return quick disconnect fitting (2). Hookup 1. When the good truck is in position, stop the engine and wait two minutes to allow the hydraulic system to bleed down. Ensure hydraulic pressure has bled off before connecting any fittings or hoses. NOTE: Maximum hydraulic pressure is not to exceed 24 304 kPa (3,525 psi). FIGURE 30-5. BLEEDDOWN MANIFOLD 1. Supply Quick Disconnect 2. Return Quick Disconnect 3. Bleeddown Manifold 2. Connect the hydraulic supply hose to the supply disconnect coupling (1, Figure 30-5). NOTE:
Failure to attach the return hose from the disabled truck to the hydraulic pressure source could cause the disabled truck hydraulic tank to overflow, or potentially damage the hydraulic power source due to lack of oil. Table 2: QD Return Fittings Qty Part Number Description 1 TA2968 Dust Cover 1 PB4685 Disconnect Fitting 1 WA3568 Swivel Adapter 1 WB0599 Fitting Qty Part Number 1 TA2968 1 PB4685 1 WA3568 1 WB0599