Komatsu — 4.7.6.B CHECKING THE BATTERY ELECTROLYTE LEVEL

MAINTENANCE PLAN 4.7.6.b CHECKING THE BATTERY ELECTROLYTE LEVEL WARNING Check the level only after stopping the engine and if necessary add distilled water only before starting work. Always wear safety goggles and waterproof gloves. To prevent gas explosions, do not use naked flames, do not smoke and avoid producing sparks due to short circuits. The battery electrolyte is dangerous; if it comes in contact with the eyes or skin, rinse with plenty of water and consult a doctor without delay. 167 The battery (1) can be reached after raising the mat on the left side and opening the door (2).

The electrolyte level in each cell must be about 6 mm above the plate edge; if necessary, top up with distilled water only. If, on the contrary, the level is low because some fluid has been spilled, add diluted sulphuric acid until reaching the concentra- tion suitable for the ambient temperature. (See “3.11.3 BATTERY”). 2 RWA06210 1 2 RWA06210 IMPORTANT • It is advisable to add distilled water before starting work, in order to prevent it from freezing. • Before putting back the cell plugs, make sure that the breather holes are not clogged. • Make sure that the connection terminals are not oxidized; if necessary, clean them and cover them with anti-oxida- tion grease. 1 RWA06220