Komatsu — 4.7.9.A CHANGING THE HYDRAULIC SYSTEM OIL AND CLEANING THE SUCTION FILTER

MAINTENANCE PLAN 4.7.9 MAINTENANCE EVERY 2000 HOURS OF OPERATION Carry out these operations together with those to be performed every 100, 250, 500 and 1000 HOURS. RWA06330 176 WARNING RWA07490 1 RWA07490 • Retract the bucket and arm cylinder completely, lower the bucket teeth to the ground and, after stopping the engine, release the residual pressures from the work equipment circuits (by operating the controls more than once) and from the tank (by slowly loosening the filling cap). • Let the oil cool down until it reaches 40-45°C (104-113°F) before carrying out any maintenance operation. • Immediately clean any area dirty with oil.

• Oils, filters, the coolant and the battery are considered special waste and must be collected and disposed of ac- cording to the anti-pollution regulations in force. 1 1 - Retract the bucket and arm cylinder completely and lower the boom until the bucket teeth touch the ground. 2 - Lower the blade to the ground. 3 - Slowly loosen the filling cap (1) in order to release the residu- al pressure. Use a 24 mm hexagon spanner. 4 - Remove the drain plug (2) and let the oil flow out, gathering it into a container with suitable capacity. Use a 32 mm hexagon spanner. 5 - Loosen the clamp (3) that holds the suction filter and remove the screws (4).

Remove the flange (5) and clean the suction filter (6). Use a 13 mm hexagon spanner. 7 RWA06310 2 RWA06320 7 RWA06310 IMPORTANT • Carefully check the filtering element grid and if it is not in perfect conditions, change it. 6 - Put back the drain plug (2), the lower flange (5), making sure that the gasket is in good conditions, and the clamp (3) of the suction pipe. 7 - Fill with the prescribed oil until reaching the correct level (7). Use oil of the prescribed type only (See “4.3 FUEL, COOL- ANT AND LUBRICANTS”).