MAN — Troubleshooting with GAC governor

Troubleshooting with GAC governor Fig. 5 Check final controlling element. ACTUATOR Remove both final controlling element cables from control unit and measure resistance. A B If value deviates, check cabling and plug. If cabling and plug are in order, exchange final controlling element. Correct value: 4,6 - 5 W W 5 Fig. 6 If resistance as per Fig. 5 is in order, connect both cables to battery voltage. The final controlling el- ement must then switch to max. position. ACTUATOR A B If it does not, the transmission linkage to the injec- tion pump control rod or the control rod itself is blocked. If linkage is in order, exchange final controlling el- ement. 6 Fig.

7 If final controlling element is in order, but still fails to move during the starting procedure, the output voltage at the final controlling element terminals of the control unit are to be checked during the start- ing procedure. ACTUATOR A B Min. value: 17 V direct voltage If no voltage is present, the control unit is defec- tive. V _ Caution: Before installing a new control unit, always check the cabling and the final controlling element circuit for short circuits. 7 126