9. WHEN FUEL GAUGE DOES NOT OPERATE (HCESPN 301, FMI 3 or 4) · Before disconnecting the connector, always turn the starting switch OFF. · Before carrying out below procedure, check all the related connectors are properly inserted. · After checking, insert the disconnected connectors again immediately unless otherwise specified. Check Table CN-51 FUEL LEVEL SENSOR 2 C GND(5V) 5 1 MCU CD-2 FUEL LEVEL SENSOR 26 CN-52 900L6ES10 6-32 YES Check resistance YES between CN-51 (5) and CN-52 (26) Starting switch : OFF Check resistance Disconnect CN-51,52 NO Spec : 50~600Ω between fuel level sender (1) and (2) Starting switch : OFF Spec :
50~600Ω See table NO Cause Remedy Defective MCU or cluster Disconnection in wiring harness or poor contact between fuel level sender-MCU Defective fuel sender Replace Repair or replace Replace Range Resistance (Ω) Range Resistance (Ω) Full 50 5/12 400 11/12 100 4/12 450 10/12 150 3/12 500 9/12 200 2/12 550 8/12 250 1/12 600 7/12 300 Empty warning 700 6/12 350 - -