11. WHEN TRAVEL SPEED 1, 2 DOES NOT OPERATE (HCESPN 167, FMI 4 or 6) · Before disconnecting the connector, always turn the starting switch OFF. · Before carrying out below procedure, check all the related connectors are properly inserted and short of fuse No. 28. · After checking, insert the disconnected connectors again immediately unless otherwise specified. 6-34 Cause Remedy YES Disconnection in Repair or replace wiring harness or Check resistance YES poor contact between CN-70 between CN-70- (1) and (2) CN-52 Starting switch : OFF Defective solenoid Replace NO Spec : 30Ω YES Check fault code Disconnect CN-70 167 active? YES Defective hydraulic Check hydraulic Starting switch :
ON system system Check voltage Check if travel between CN-70 NO speed lamps( , (1) and (2) ) change when pressing the travel Starting switch : ON Disconnection in Repair or replace NO speed switch on Spec : 20~30 V wiring harness or the cluster Disconnect CN-70 poor contact between CN-70- Starting switch : ON fuse No. 28 YES Defective cluster Replace Check MCU Y R G NO Defective MCU Replace NO Starting switch : ON FUSE No.28 MCU TRAVEL HIGH SOLENOID 2 TRAVEL SPEED SOL 20 1 CN-70 CN-52 900L6ES04 Cause Remedy Disconnection in wiring harness or poor contact between CN-70- CN-52 Defective solenoid Defective hydraulic system Disconnection in wiring harness or poor contact between CN-70- fuse No.
28 Defective cluster Defective MCU Repair or replace Replace Check hydraulic system Repair or replace Replace Replace FUSE No.28 MCU TRAVEL HIGH SOLENOID 2 TRAVEL SPEED SOL 20 1 CN-70 CN-52 900L6ES04 900L6ES04 2 1