Kaiyi — 2. MAJOR COMPONENT

(3) Causes of troubles and remedies The motor rotates reversely ② The speed does not reach set value ③ 7-24 Phenomenon Possible cause Remedy Pressure does not increase ·Safety valve in circuit is not correctly. ·Relief valve does not function well. a) Sticking of plunger b) Clogging of plunger throttle. ·Seat of plunger does not funtion well. ·Set valve at correct valvue. ·a) Repair or replace stuck section. b) Disassemble and repair plunger. ·Check seat section. Replace it, if damaged. Pressure rises ·Overload. ·Seizure of moving parts. ·Brake is not applied with release perssure. ·Brake piston sticks. ·Spool sticks. ·Fricrtion plate is seized. ·Remove load. ·Check and repair.

piston/shoes, cylinder, valve plate, etc. ·a) Check and repair circuit. b) Check time delay valve for brake. ·Disassemble and check it. ·Disassemble and check it. ·Disassemble and check it. Replace seized one. Phenomenon Possible cause Remedy Motor rotates reversely. ·Motor is assembled to rotate reversely. ·Piping is connected to inlet and outlet reversely ·Confirm this, and reassemble it ·Correct piping. Phenomenon Possible cause Remedy Speed does not reach set value ·Oil flow rate is insufficient. ·Oil temp is high and oil leaks abnormally. ·Sliding parts are worn or damaged. ·Check pump's delivery flow and circuit to motor. ·Reduce oil temp. ·Replace damaged parts.