PACCAR PX-7 — Starting After the Fuel Tank Has Run Dry or After Fuel System Service has been Performed

ENGINE MAINTENANCE - Maintenance Procedures 3. Tighten the fuel filter cap by rotating it clockwise until the filter cap O-ring makes contact with the fuel module. Then tighten the filter cap to 30 lb-ft (40 N·m) as specified on the filter cap. 4. If installing a new fuel filter on a PX-7, loosen the fuel priming pump knob by rotating it counter-clockwise. During this time the pumping resistance will increase but the full time is required to fully prime the fuel system. Then tighten the knob by rotating it clockwise. the engine to start. If the starter is engaged for longer than 20 seconds without starting, additional priming pump actuation may be necessary.

2 CAUTION CAUTION If the engine is cranked exces- sively Starter Protection will be triggered and starter engage- ment will be restricted for 10 mi- nutes. NOTE Operate priming pump at a maxi- mum rate of 30 strokes per mi- nute to prevent damage to pump. The PX-9 uses an electric pri- ming pump. If installing a new fuel filter on a PX-9 engine first vent the fuel system at the quick- disconnect fitting at the pressure side filter head inlet. The vent overflow may be routed back to the fuel tank, or, into a vented container.

Cycle the ignition switch to the ON position every 2 minutes (to power the electric lift pump) until fuel appears in the chassis-mounted fuel filter hous- ing and a solid stream of fuel flows out of the vent., then skip to Step 6. 6. Check for leakage at the fuel filter cap. Tighten if necessary. 8. Check the system for leakage while idling. Then turn the engine off and check the system again for leakage. WARNING Check the fuel filter for signs of leakage. DO NOT smoke or al- low an open flame in close prox- imity. Failure to do so could ignite a fire or cause an explosion which could result in serious in- jury to you and/or bystanders.

Failure to comply may result in death, personal injury, equipment or property damage. Starting After the Fuel Tank Has Run Dry or After Fuel System Service has been Performed Procedure for starting the engine after running out of fuel. Follow the steps below to restart the engine: 5. Operate the priming pump by moving the knob in and out for 150 seconds. 7. Start the engine and allow it to idle for several minutes. Note that it could take up to 15 seconds of cranking for 64 Y53-1183-1E1 (04/16/18)