The contact handling procedure is described in Point A 1. 4. Cable/wires, general Heat and diesel resistant PVC or PUR insulated copper stranded wires complying with DIN 72551 should be used. For strength reasons, the minimum permissible wire cross section is 0.5 mm 2. Specified cross sections: 0.5 – 1.0 mm 2 for all instrumentation and control lines 1.0 – 2.5 mm 2 for all 12 V or 24 V supply lines 4.0 – 6.0 mm 2 for supply leads from the battery to the connection points Observe Points 5.1 and 6. when selecting the cross section. Cables not subjected to mechanical load can also be designed as leads with reduced insulation thickness. A low-capacitance special cable (e.g.

3x1.0 mm 2 Radox 125) may be necessary for the control rod position transducer line if this involves a longer wiring harness. For protection purposes, the lines should be routed in a non-woven PVC tube complying with DIN 40621 which must be diesel and oil-proof in the engine compartment. 4.1Wiring harnesses The wires of the EDC system are combined in a wiring harness and must not be routed together with other systems. Malfunctions attributable to the wiring harness are not expected, if the specified limits are complied with. The specified limits should be considered as extreme values, i.e. lower values are to be aimed for.

In addition to the physical limits for wiring harnesses and the corresponding measur- ing procedure, concrete proposals with regard to the design of the wiring harness are also provided. D Wiring harnesses which, based on experience, fulfil the physical limits. Length up to 6.0 m, wiring harnesses made up of individual conductors, with loose to close bundling of conductors. The cables leading to the control rod position transducer should be made up of either twisted conductors or a 3-core cable.

Length up to 8.0 m, wiring harnesses made up of individual conductors, loosely arranged in a plastic tube, while closely routed wires (bundled every 50 cm, twin wires, twisted wires) are used for supply and return lines to pulsed actuators (inductive coupling) and a 3-core low-ca- pacitance cable is used for the supply leads to the control rod position transducer. Length over 8.0 m, wiring harnesses in which the conductors considered as sources of inter- ference (e.g. pulsed actuator lines) and interference-sensitive lines (sensors) are bundled sep- arately, and a 3-core low-capacitance special cable is used for the supply lines to the control rod position transducer are realized by. 122