MAN Nutzfahrzeuge — 6. Voltage supply

This control or slide valve position error is dependent on the evaluator circuit and must be deter- mined for each project. D Explanations Test Measurement of a representative batch of wiring harnesses in accordance with 5.3. The effective capacitance during EDC operation and its scatter (statistical evaluation) must be determined. D Remedy for excessively high scatter of the capacitive loads between the supply lines to the con- trol rod position transducer Twisting of the three individual conductors at a minimum rate of 20/m Use of a 3-core low-capacitance cable 6.

Voltage supply The EDC systems should be connected to the general vehicle electrical system in accordance with the terminal connection diagram. Three criteria must be taken into consideration when connecting the supply voltage: Low line resistance in the supply and return lines. If this point is disregarded, cold starting diffi- culties can arise as the minimum voltage of the control unit is below specified values. The ground lead should be routed separately and not over the body as high contact resistances can occur at the transition points which change negatively due to ageing and environmental in- fluences.

Routing EDC supply currents and starter current via common cables/body sections can also re- sult in starting difficulties. Major interfering influences caused by switching peaks of motors, switches and relays which can cause malfunctions in the control unit. The following guidelines should be complied with to ensure these criteria do not have negative ef- fects on the system: The supply voltage should be connected directly to the battery at positive and negative terminals. If this type of connection cannot be implemented, care must be taken to ensure that the distance between the alternator and battery is as small as possible.

This ensures reduced residual ripple in the vehicle electrical system. The supply and return lines should be kept short in order to avoid excessive voltage drops. Further measures are suggested in order to ensure effective and trouble-free operation with the EDC system: The sensor or actuator ground must not be coupled with the vehicle ground otherwise interfer- ence voltages can flow into the system. The control unit features a no-lead diode for the actuating solenoid. The positive supply line of the actuating solenoid should therefore be positioned electrically “close” to the control unit and electri- cally “far from” the EDC power supply.

Otherwise, the self-induction peak of the solenoid coil can spread relatively unhindered in the vehicle electrical system. 127