MAN Nutzfahrzeuge — Notes on design and assembly for wiring harnesses of electronic systems

Notes on design and assembly for wiring harnesses of electronic systems 12. Cable straps must be provided and firmly tightened at the specified points. 13. Refer to page 4 for general information. B. Installation 1. Preferred position: Connector output facing downward 2. Water ingress in the wiring harness (insulating conduit) must be prevented. 3. Water is not permitted in the area of the plug connector. 4. Protect openings in the wiring harness from direct water. 5. Do not arrange wiring harness branches which could under certain circumstances against the spray direction of water. 6. Implement the following measures if water ingress in the wiring harness cannot be avoided.

6.1 The wiring harness must be set lower in the vicinity of the plug connection. 6.2 In addition, an interruption in the insulating tube is necessary at the lowest point (drip-off point). Interruption: approx. 30 – 60 mm. Perforation over a length of: approx. 30 – 60 mm. 6.3 Ensure sufficient spacing from the interruption up to the plug connection. 6.4 Protect interruption from direct water. 6.5 A rubber grommet with individual core leadthroughs is required for conditions subject to extreme water load. 7. The fit of the rubber grommet of the plug connection must not be subject to impermissible load when installing the wiring harness.

7.1 Use angled grommets if necessary (more difficult to install). 8. The rubber grommet must not be inclined at the cable outlet. 9. The following points must be observed when using cable cross sections 2 (e.g. 0.35 mm 2 , 0.5 mm 2 ): Only protected cables should be installed in the engine compartment (e.g. in insulating conduit) A right-angled (r the maximum permissible tensile force (100 N) may be exceeded at the outer lines. 10. The cable must not be subject to tensile load (e.g. connection to a fixed part) when installing the plug connectors otherwise there may be a risk of chafing corrosion at the plug connection (contact to blade).

The plug connection must be arranged such that the contacts have sufficient clearance, i.e. “float”. 132