Cab Heater and Air Conditioner, Valeo 83.00 General Information Thermodynamic Principles water reaches a temperature of 212°F (100°C). This is the boiling point of water at standard sea level conditions. Air conditioning works by removing heat and humidity from the air in the passenger compartment. This is accomplished through three thermodynamic prin- ciples; the principles and how they work in a vehicle are described below. Heat Transfer Even though it continues absorbing more heat, the water temperature cannot go above 212°F (100°C) so that as it boils, it changes from liquid water to the vapor commonly called steam.
It continues to absorb heat and boil until the entire pound of water has passed off into the atmosphere as steam. Under nor- mal conditions the steam rapidly gives off its heat to the surrounding air, but it rises from the water at a temperature of 212°F (100°C). Heat always moves from warm areas to cold ones. Cold does not move from cold areas to warm ones. Air conditioners work by absorbing heat and carrying it away, not by generating cold air, although since the heat has been absorbed from it, the air coming from an air conditioner feels cold.
In other words, the water and vapor temperatures can rise only 180°F (from 32°F to 212°F [0°C to 100°C]) at sea level pressure, even though many more than 180 BTUs are absorbed. The heat ab- sorbed by the liquid in the process of boiling dissi- pates from the vapor into the cooler surrounding air, and the vapor condenses back to water. If two objects, one hot, one cold, are near each other, the heat energy in the warmer object will al- ways travel to the lower heat energy area of the cooler object, until they are equal temperature. Higher energy flows to low energy; low energy never flows to high energy.
The heat transferred as substances change their physical state, such as water boiling to vapor, and vapor condensing back to water, is called the latent (or hidden) heat of vaporization. Latent heat varies widely among various materials. The British Thermal Unit (BTU) is used to determine the amount of heat transferred from one object to another. One BTU is the amount of heat energy re- quired to raise the temperature of 1 pound (0.45 kg) of water 1°F (0.55°C). Water has a latent heat of vaporization of 970 BTUs and a boiling point of 212°F (100°C). This means that 1 pound (0.45 kg) of water at 212°F (100°C), will absorb 970 BTUs when changing completely to vapor at 212°F (100°C).
Conversely, the vapor will give off 970 BTUs when condensing back to water at 212°F (100°C). For example, to raise the temperature of 1 pound (0.45 kg) of water from 32°F to 212°F (0°C to 100°C), one BTU must be added for 1°F (0.55°C) rise in temperature, a total of 180 BTUs. Conversely, in order to lower the temperature of 1 pound (0.45 kg) of water from 212°F to 32°F (100°C to 0°C), 180 BTUs must be removed from the water. Latent Heat of Vaporization This heat energy transfer, occurring when a liquid boils or a vapor condenses, is a basic principle of all conventional refrigeration systems. For a liquid to be a refrigerant, it must also have a low boiling point.
That is, the temperature at which it boils must be lower than the temperature of the sub- stance to be cooled. As a liquid boils, it absorbs heat without raising the temperature of the resulting gas. When gas con- denses, changing back to a liquid, it gives off heat without lowering the temperature of the resulting liquid. R–134a is a TFT refrigerant, less damaging to the atmosphere than CFC refrigerants such as R12. R–134a has a temperature/pressure relationship which makes it suitable for vehicle air conditioning systems.
For example, when a container holding 1 pound (0.45 kg) of water at 32°F (0°C) is heated, the tem- perature of the water rises 1°F (0.55°C) with each BTU energy that the water absorbs. After it absorbs 180 BTUs, raising its temperature 180°F (100°C), the Business Class M2 Workshop Manual, Supplement 18, September 2010 050/1