Cab Heater and Air Conditioner, Valeo 83.00 Safety Precautions Safety Precautions have a slightly sweet odor that is difficult to detect. Frequent leak checks and air monitoring equipment are recommended to ensure a safe working environ- ment. Whenever repairs are made to any air conditioner parts that hold R–134a refrigerant, you must recover, flush (if contaminated), evacuate, charge, and leak test the system. In a good system, refrigerant lines are always under pressure and you should discon- nect them only after the refrigerant charge has been recovered (discharged) at the service valves. IMPORTANT:

When servicing an R–134a air conditioning system, use only service equipment certified to meet the requirements of SAE J2210 (R–134a recycling equipment). The equipment should be operated only by qualified personnel who are familiar with the recycling station manu- facturer’s instructions. Refrigerant R–134a is safe when used under the right conditions. Always wear safety goggles and non-leather gloves while recovering, evacuating, charging, and leak testing the system. Do not wear leather gloves. When refrigerant gas or liquid con- tacts leather, the leather will stick to your skin. Because of its very low boiling point, refrigerant must be stored under pressure.

To prevent the refrigerant containers from exploding, never expose them to temperatures higher than 125°F (52°C). WARNING On R–134a refrigerant systems, polyalkylene glycol (PAG) oil is used in the compressor. When handling PAG oil, observe the following guidelines: Use care to prevent refrigerant from touching your skin or eyes because liquid refrigerant, when exposed to the air, quickly evaporates and will freeze skin or eye tissue. Serious injury or blindness could result if you come in contact with liquid refrigerant. Keep the oil free of contaminants. Do not expose the air conditioning system or the PAG oil container to air for more than five minutes.

PAG oil has a high moisture absorp- tion capacity and the oil container should be immediately sealed after each use. Refrigerant splashed in the eyes should be rinsed with lukewarm water, not hot or cold. Do not rub the eyes. Apply a light bandage and contact a physician right away. Use care when handling. Spilled oil could dam- age painted surfaces, plastic parts, and other components such as drive belts. Refrigerant splashed on the skin should be rinsed with lukewarm water, not hot or cold. Do not rub the skin. Apply a light coat of a nonmedicated ointment, such as petroleum jelly. Contact a physician right away. Never mix PAG oil with other types of refriger- ant oil.

R–134a refrigerant does not burn at ambient tem- peratures and atmospheric pressure. However, it can be combustible at pressures as low as 5.5 psig (139 kPa absolute) at 350°F (177°C) when mixed with air concentrations that are greater than 60 percent. WARNING R–134a air conditioning systems should not be pressure tested or leak tested with compressed air. Combustible mixtures of air and R–134a may form, resulting in a fire or explosion that could cause personal injury or property damage. Always work in an area where there is a constant flow of fresh air when the system is recovered, evacuated, charged, and leak tested.

R–134a vapors Business Class M2 Workshop Manual, Supplement 18, September 2010 100/1