Cab Heater and Air Conditioner, Valeo 83.00 Troubleshooting table and record them in Table 1 under the "Pub- lished Readings" heading. Refrigerant Pressure Test Gauge Diagnosis 13. If the actual dash outlet temperature is within the range of the published values, then the system is performing satisfactorily. If the actual temperature is not within the published value, use the other readings such as high-side or low-side (suction or discharge) pressures and compressor cycling information to begin diagnosing the system. See Table 2 for diagnosis of the system using refrig- erant pressure test gauge readings.
Check the spe- cific component or condition mentioned in the Pos- sible Cause column to help determine the cause of a problem with the system. 14. If Z-shaped brackets were used to lock the vis- cous fan, remove the brackets.
A/C Performance Test Data Test Data Item Published Readings (see step 12) Actual Readings Ambient Temperature Relative Humidity (RH) _____°F (°C) _____% RH Center Dash Outlet Temperature _____°F (°C) to _____°F (°C) _____°F (°C) High-Side Pressure _____ psi (kPa) to _____ psi (kPa) _____ psi (kPa) Low-Side Pressure _____ psi (kPa) to _____ psi (kPa) _____ psi (kPa) Compressor Cycling yes/no yes/no Compressor On/Off Time (only if cycling) on _____ sec on _____ sec off _____ sec off _____ sec Table 1, A/C Performance Test Data System Diagnosis Using Refrigerant Pressure Readings Suction Pressure (low side) Discharge Pressure (high side) Possible Cause Remedy High Low Worn compressor.
Replace compressor. Be sure to identify and correct cause of failure (e.g. system contamination, incorrect oil charge, leaks, etc.) High Normal Thermal expansion valve (TXV) stuck open. Replace TXV. Clean bugs, dirt, and any debris or obstructions blocking airflow through the condenser. Straighten condenser fins as necessary. Make sure engine fan is working properly and that fan shroud is in place. Restricted condenser air flow. High High Air or moisture in the refrigerant. Recover and evacuate the system, charge system with proper amount of pure R-134a refrigerant. Replace the R/D if moisture was determined to be an issue. System overcharged.
Recover and evacuate the system, charge system with proper amount of pure R-134a refrigerant. Blockage downstream of measurement point and before expansion valve. Remove the blockage or replace the component with the blockage as necessary. Determine cause of blockage and make further repairs as required. Business Class M2 Workshop Manual, Supplement 13, March 2008 300/2