REINFORCING SIDE MEMBERS REMOVAL OF THE REINFORCING SIDE MEMBERS (For versions with front lift only) 1 - Remove the front lift valve block. (For details, see «REMOVAL OF THE VALVE BLOCK»). 2 - Remove the air reservoir and the battery support. (For details, see «REMOVAL OF THE AIR RESERVOIR AND BATTERY SUPPORT») 3 - Attach a hoist to the side member to be removed and put the lifting sling under slight tension. Side member: 45 kg (99 lb.) F0045010 4 - Right side member (1): Unscrew and remove the front bolts (2) complete with their washers and recover the spacers (3). 3 1 1 2 F0045020 5 - Left side member (4) :
Unscrew and remove front bolts (2) as per the right side member and the two rear bolts (5) complete with washers. 1 4 5 2 2 F0045030 REFITTING THE SIDE MEMBERS Refitting is the reverse of removal. 1 Bolts M16: 214±21 Nm (158±15.5 lb.ft.) Bolts M20: 455±21 Nm (335±15.5 lb.ft.) 30-113