Deutz — 4.1 CONFIGURATION

SERDIA PARAMETERS Figure: Example of a choice of configuration parameters. EXPLANATION OF THE FUNCTION SWITCH ECU->PC: The configuration data is read from the ECU and is displayed. PC->ECU: Updated configuration data is uploaded to the ECU. In order for the uploaded data to be permanent, you must activate the "Save in ECU" switch for the ECU. Open file: The configuration data is read and displayed from a hex file. Save in file: The configuration data is saved in a hex file. The engine number will be suggested as file name for storage on from SERDIA 2.5. This suggestion is not compulsive; other file names may be chosen nevertheless. Then confirm with OK. The file (i.e.

the engine data record) is then saved under the name hex. Save in ECU (applies for EMR only): The configuration data are permanently saved in the ECU. changes to the con- figuration have to be reported! ATTENTION! All changes to the configuration have to be reported! The reporting procedure is described in Service Bulletin 0199-99-9287. Previous: The reporting procedure is described in Service Bulletin 0199-99-9287 . Next: Displays data for the next screen page. Print ON: A print-out is made of the configuration data currently displayed. 4.1.1 EMR . 1 - The following table gives an overview of the possible configuration parameters.

2 - Settings that cannot be made while the engine is running are identified by the message ”Stop engine” 3 - SERDIA only displays one page at a time. 20-21