Deutz — 4.1 CONFIGURATION

SERDIA PARAMETERS EMR PARAMETERS CONFIGURABLE WITH LEVEL III 20-22 MK 3 TTG Parameter Unit Min. Max. typ Wert Description Page 1: General overview Engine serial number 0 4,2x109 12345678 8 digits Number of cylinders 4 8 ace. to engine type No. of teeth eng. speed 2 48 1013 44 1012 18 200 129 PassLevel 1 (OEM) 0 4,2x109 PassLevel 2 (Service) 0 4,2x109 Page 2: Only for BOSCH EDO inline pumps RefVal.EDC RackPos 20 mm 0 65535 4000 RefVal.EDC RackPos. 0 mm 0 65535 1800 RefVal.EDCValueRefCoil 0 65535 1800 AutoCalib:Current % 0 100 78,2 AutoCalib:WaitingTime s 0 100 1,0 Page 3: Engine speed settings Idling speed 1/min 500 4000 770 Idling speed engine ( Fixed eng.

speed 1 1/min 500 4000 1000 Fixed speed setpoint 1 Fixed eng. speed 2 1/min 500 4000 1000 Rated speed engine Rated speed 1/min 500 4000 2300 Fixed speed setpoint 2 Rated speed limp home 1/min 500 4000 2000 Rated speed upon failure of speed sensor 1 Overspeed 1/min 500 4000 3000 Limit overspeed Recov. speed overrun 1/min 500 4000 2000 Reset limit overspeed average:0=1 turn, 1=2 turns 0 1 0 Average speed smoothing Page 4: Speed governor SpeedGvnr: P part % 0 100 18/4,0 Gain factor P part (genset/automotive) SpeedGvnr: I part % 0 100 10/10,0 Gain factor I part (genset/automotive.) SpeedGvnr: D part % 0 100 10/5,0 Gain factor D part (genset/automotive) SpeedGvnr:

damping % 0 100 90/65,1 Damping factor w. minor speed fluctuation (genset. /automotive) SpeedGvnr: damping range 1/min 0 100 15/80,0 Speed governor: damping range (gensets/ automotive) Engine speed ramp down 1/min/s 0 10000 100 Max. contr. speed setpoint speed ramp down Engine speed ramp up 1/min/s 0 10000 10,1 Max. contr. speed setpoint speed ramp up MK 3 TTG Parameter Unit Min. Max. typ Wert Description Page 5: Position governor Only change the following 10 parameters in consultation with the head office Posgvnr: P part % 0 100 10 Gain factor P part Posgvnr: 1 part % 0 100 5 Gain factor I part Posgvnr: D part % 0 100 5 Gain factor D part Posgvnr:

DT2 part % 0 100 10 Gain factor DT2 part Posgvnr: Gain % 100 200 180,1 Gain factor with minor speed fluctuation Posgvnr: gain range mm 0 1 0,25 Gain fluctuation range for gain factor QuickCurrentDecSteepness 1/min 0 65535 40000 QuickCurrentDecTime ms 0 65535 50 Page 6: Functions