John Deere 450DLC, 650DLC, and 850DLC Excavators — Clean Cab Fresh Air and Recirculating Air Filters

Maintenance—Every 500 Hours Clean Cab Fresh Air and Recirculating Air Filters IMPORTANT: Replace filters after the sixth cleaning. Removing Cab Fresh Air Filter: TX1000868 –UN–03DEC05 1. Unlock, and open left cab side cover (1) below cab door window. 2. Squeeze tab (2) on each side of the filter to remove. Removing Cab Recirculating Air Filter: 1. Move operator’s seat forward to access filter (3) located under the rear deck. 2. Squeeze tab (4) on right side of filter to remove. TX1000869 –UN–03DEC05 Cleaning Filters: 1. Clean filters in one of 2 ways. CAUTION: Reduce compressed air to less than 196 kPa (1.96 bar) (28.4 psi) when using for cleaning purposes.

Clear area of bystanders, guard against flying chips, and wear personal protection equipment including eye protection. Use compressed air opposite to the normal air flow. Wash filters with water. Soak the filters in warm, soapy water for 5 minutes. Flush filter. Allow filter to dry before installing. TX1000870 –UN–03DEC05 2. Install filter. 1—Side Cover 2—Fresh Air Filter Tab (2 used) 3—Recirculating Air Filter 4—Recirculating Air Filter Tab VD76477,0000369 –19–31OCT06–1/1 3-7-10 010609 PN=165