John Deere 450DLC, 650DLC, and 850DLC Excavators — Counterweight Removal

Operation—Operating the Machine 7. Set variable orifice (A) by turning in direction of arrow until closed. Then open orifice two turns. Adjust as required to achieve desired counterweight lowering speed. Every 1/8 turn of variable orifice changes lowering cycle time approximately 6 seconds. IMPORTANT: Linkage pivot areas may bind if not properly lubricated resulting in failure of the counterweight lift cylinder to raise counterweight to full height. T8172AF –UN–20FEB94 8. Grease all pivot areas of counterweight lift linkage the FIRST TIME and every third time the counterweight device is operated. A—Variable Orifice DW90712,00001F0 –19–12SEP08–4/12 9.

Loosen jam nut and turn handle of shutoff valve (A) (located through opening under the engine) counterclockwise to open hydraulic pressure to counterweight lift cylinder (B). A—Shutoff Valve B—Lift Cylinder T8172AP –UN–20FEB94 Continued on next page DW90712,00001F0 –19–12SEP08–5/12 2-3-17 010609 PN=87