John Deere 700H Crawler Dozer — Charge Pump, Disassemble and Assemble

Hydrostatic System 18. Install flange adapter (B). 19. Install socket head cap screws and washers (A). Tighten to specifications. Hydrostatic Pump—Specification Flange Adapter/End Cap-to-Hydrostatic Pump— Torque 298 (220 lb-ft) ......................................................................... T118269B –UN–20NOV98 20. Install hydrostatic pumps. (See Remove and Install Hydrostatic Pump in this group.) 21. Calibrate transmission controller.