John Deere 700H Crawler Dozer — Charge R134a System

Heating and Air Conditioning TM1859 (14JUL04) 18-1830-19 700H Crawler Dozer 071404 PN=463 Charge R134a System SPECIFICATIONS Refrigerant Weight 1.5 Kg (3.5 lbs) ESSENTIAL TOOLS JT02045 R134a Refrigerant Recovery/Recycling and Charging Stationa aJT02046 and JT02050 recovery and charging stations can be substituted for the JT02045 station. CAUTION: Do not remove high pressure relief valve (A). Air conditioning system will discharge rapidly causing possible injury. IMPORTANT: Use correct refrigerant recovery, recycling and charging stations. DO NOT mix refrigerant, hoses, fittings, components or refrigerant oils. –19–22FEB95 1. Connect refrigerant recovery, recycling and charging station.

(See R134a Refrigerant Recovery, Recycling and Charging Station Installation Procedure in this group.) T8422AC 2. Evacuate the system. (See Evacuate R134a System in this group.) A—High Pressure Relief Valve B—High Pressure Test Port NOTE: Before beginning to charge air conditioning C—Red Hose system, the following conditions must exist: D—Blue Hose Engine STOPPED, the pump must be capable of E—High Pressure Hose pulling at least 28.6 in. Hg vacuum (sea level). F—Low Pressure Hose G—Low Pressure Test Port Subtract 3.4 kPa (34 mbar) (1 in. Hg) from 98 kPa H—Refrigerant Recovery/Recycling and Charging (980 mbar) (29 in. Hg) for each 300 m (1000 ft) Station elevation above sea level. 3.

Follow the manufacturer’s instructions and charge the system. 4. Add refrigerant until system is charged with 1.5 Kg (3.5 lbs). Specification Refrigerant—Weight.......................................................... 1.5 Kg (3.5 lbs) Continued on next page CED,TX14826,12325 –19–04MAY00–1/2 18 1830 19 SPECIFICATIONS Refrigerant Weight 1.5 Kg (3.5 lbs)