John Deere 700H Crawler Dozer — Leakage Test

Heating and Air Conditioning 5. Do air conditioner checks and tests in Operation and Test Manual, Groups 9005-10 and 9031-25. CED,TX14826,12325 –19–04MAY00–2/2 18 1830 Leak Testing 20 SERVICE EQUIPMENT AND TOOLS JT02081 Electronic Leak Detector 1. Inspect all lines, fittings, and components for oily or dusty spots. When refrigerant leaks from the system, a small amount of oil is carried out with it. 2. A soap and water solution can be sprayed on the components in the system to form bubbles at the source of the leak. 3. If a leak detector is used, move the leak detector probe under the hoses and around the connections at a rate of 25 mm (1 in.) per second. 4.

Some refrigerant manufacturers add dye to refrigerant to aid in leak detection. CED,OUO1066,309 –19–30MAR00–1/1 TM1859 (14JUL04) 18-1830-20 700H Crawler Dozer 071404 PN=464 SPECIFICATIONS Leak Detector Probe Rate 25 mm (1 in.) per Second