John Deere 700H Crawler Dozer — System Cleaning Procedures

Heating and Air Conditioning TM1859 (14JUL04) 18-1830-21 700H Crawler Dozer 071404 PN=465 Air Conditioner System Cleaning Procedures Flushing: Flushing the system or component is a • TY16134 Air Conditioning System Flushing Solvent cleaning process using a liquid solvent to remove oil and debris. Purging is always necessary after flushing Purging: Purging the system or a component is a to remove solvent from the system or component. cleaning process using a gas to force liquid from the system. Purging alone will not remove refrigerant oil Following is a list of situations that require a flushing from the system. procedure be done: Following is a list of situations that require a purging 1.

The compressor has an internal failure. procedure be done: 2. No oil remains in used compressor. 3. Oil drained from compressor appears or smells • After flushing system with solvent, to prevent oil overheated. dilution. 4. System was contaminated with a mixture of • System was contaminated with nitrogen or two refrigerant oils. refrigerants. 5. System was left open to the atmosphere long • System was left open to the atmosphere and enough for dirt, moisture, or debris to enter the flushing could not be performed. tubing or components. • Installation of new lines, condenser, or evaporator 6. System has an internal blockage. was required.

The following solvent is recommended for flushing air Evacuating: Evacuating the system is a process to conditioner systems. Use only solvents with an remove air and moisture from the system, creating a equivalent MSDS. vacuum. CED,TX03399,2291 –19–09DEC98–1/1 18 1830 21