Perkins — Perkins 1204F-E44TA and 1204F-E44TTA Industrial Engine Systems Operation Manual

UENR4490-01 119 Basic Engine 4. Calculate the difference between the lowest measurement and the highest measurement of the four locations. This difference must not be greater than 0.03 mm (0.001 inch) for every 25 mm (1.0 inch) of the radius of the flywheel. The radius of the flywheel is measured from the axis of the crankshaft to the contact point of the dial indicator. Concentricity of the Flywheel Housing Note: This check must be made with the flywheel and the starter removed and the bolts for the flywheel housing tightened lightly. Flywheel Runout Illustration 115 g01199468 Typical example Illustration 114 g01321858 Typical example 1. Install Tooling (A). See illustration 115 . 1.

Install Tooling (A) in illustration 114 , as shown. 2. Set the pointer of the dial indicator to 0 mm (0 inch). 2. Set the pointer of the dial indicator to 0 mm 3. Check the concentricity at intervals of 45 degrees around the flywheel housing. (0 inch). 3. Turn the flywheel. Read the dial indicator for every 45 degrees. 4. Calculate the difference between the lowest measurement and the highest measurement. This difference must not be greater than the limit that is given in Table 16 . 4. Calculate the difference between the lowest measurement and the highest measurement of the four locations. This difference must not be greater than 0.30 mm (0.012 inch). Note:

Any necessary adjustment must be made on the flywheel housing. Then, recheck the concentricity. i02406200 Flywheel Housing - Inspect Alignment of the Flywheel Housing Note: This check must be made with the flywheel and the starter removed and the bolts for the flywheel housing tightened to the correct torque. Table 15 Required Tools Tool Part Number Part Description Qty A 21825617 Dial Gauge 1