Perkins — Perkins 1204F-E44TA and 1204F-E44TTA Industrial Engine Systems Operation Manual

UENR4490-01 99 Air Inlet and Exhaust System The original valve guides are bored into the cylinder head. When new valve guides(1) are installed, new valves and new valve seat inserts must be installed. The cylinder head must be rebored in order to install the new valve guide. For more information, contact your distributor or your dealer. i05477270 Diesel Exhaust Fluid Quality - Test Required Tooling Table 8 Illustration 90 g03370553 Calibration point for distilled water Test Procedure 1. Follow the instructions included with Tooling (A) to calibrate the waterline of the meter. 2. Clean Tooling (A) and apply two drops of Diesel Exhaust Fluid (DEF) collected from the DEF tank.

Illustration 89 g03370564 A typical example of Tooling (A) Illustration 91 g03370573 Typical reading for DEF in good condition 3. Inspect the DEF in Tooling (A). If the DEF does not meet specification, replace the DEF in the tank with new DEF. Refer to Operation and Maintenance Manual for more information. The new DEF must meet ISO 22241 standards. Required Tools Tool Part Number Part Description Qty A T400195 Refractometer (DEF) 1