hitachi — Pump Failure MC Fault Code 11200

TROUBLESHOOTING / Troubleshooting A PUMP FAILURE MC FAULT CODE 11200 YES Faulty MC. Connector (Harness end of connector viewed from Check if voltage be- tween terminal #D10 of harness end of connector MC-D and machine is 0 V. the open side) MC Connector MC-D Pump 1 Delivery Pressure Sensor A Shorted circuit in harness between MC and engine pump 1 delivery pressure sensor. · Key switch: ON NO #D10 1 2 3 T183-05-04-009 T5-5-75 Fault Code Trouble Cause Influenced Control 11200-3 Abnormal Pump 1 Delivery Pressure Sensor High Voltage Voltage:

4.5 V or higher • HP Mode Control • Travel HP Mode Control • E Mode Control • Travel Torque-Up Control • Arm Regenerative Control • Digging Regenerative Control • Auto-Power Lift Control • Travel Motor Swash Angle Se- lection Control 11200-4 Abnormal Pump 1 Delivery Pressure Sensor Low Voltage Voltage: Less than 0.25 V • HP Mode Control • Travel HP Mode Control • E Mode Control • Travel Torque-Up Control • Arm Regenerative Control • Digging Regenerative Control • Auto-Power Lift Control • Travel Motor Swash Angle Se- lection Control Disconnect connector YES Open Circuit harness MC-D of MC. between MC and pump 1 Check for continuity in delivery pressure sensor.

YES harnes between terminal #D10 of harness end of Disconnect connector connector MC-D in MC of pump 1 delivery and terminal #2 in pump To A pressure sensor. NO 1 delivery pressure Check if voltage NO sensor. between terminals #1 and #3 of harness end Check if voltage YES Open circuit in harness of connector is 5±0.5 between terminal #1 of between MC and pump 1 V. harness end of delivery pressure sensor Switch pump 1 delivery connector in pump 1 (terminal #3). pressure sensor with · Key switch: ON NO delivery pressure pump 2 delivery sensor and machine is Open circuit in harness pressure sensor and specification. between MC and pump 1 retry.

NO delivery pressure sensor Check if fault code is · Key switch: ON (terminal #1). switched. · Specification: More than 0.25 V, Less than 4.5 V Faulty pump 1 delivery YES pressure sensor. Open Circuit harness between MC and pump 1 delivery pressure sensor. Faulty pump 1 delivery pressure sensor. YES Disconnect connector of pump 1 delivery pressure sensor. Check if voltage between terminals #1 NO and #3 of harness end of connector is 5±0.5 V.