hitachi — MC Fault Code 11303

TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11303 Disconnect connector MC-C of MC. Check for continuity in harnes between terminal #C3 of harness end of connector MC-C in MC and terminal #2 in arm roll-in pilot pressure sensor. YES Open circuit in harness between MC and pressure sensor. YES To A Disconnect connector of arm roll-in pilot pressure sensor. Check if voltage between terminals #1 and #3 of harness end of connector is 5 ± 0.5 Open circuit in harness between MC and arm roll-in pilot pressure sensor (terminal #3). Switch arm roll-in pilot pressure sensor with other pressure sensor and retry. Check if fault code disappears . NO NO · Key switch:

ON Check if voltage between terminal #1 of harness end of connector in arm roll-in pilot pressure sensor and machine is specification. YES NO Open circuit in harness between MC and arm roll-in pilot pressure sensor (terminal #1). · Key switch: ON · Specification: More than 0.25 V, Less than 4.75 V NO Faulty arm roll-in pilot pressure sensor. YES Check if voltage be- tween terminal #C3 of harness end of con- nector MC-D and machine is 0 V. A Shorted circuit in harness between MC and arm roll-in pilot pressure sensor. Connector (Harness end of connector viewed from the open side) · Key switch:

ON NO MC Connector MC-C Pilot Pressure Sensor (Arm Roll-In) #C3 C23 C31 T5-5-81 Fault Code Trouble Cause Influenced Control 11303-3 Abnormal Arm Roll-In Pilot Pressure Sensor High Voltage Voltage: 4.75 V or higher • HP Mode Control • Arm Regenerative Control • Digging Regenerative Control • Auto-Power Lift Control 11303-4 Abnormal Arm Roll-In Pilot Pressure Sensor Low Voltage Voltage: Less than 0.25 V • HP Mode Control • Arm Regenerative Control • Digging Regenerative Control • Auto-Power Lift Control ES Faulty MC. C1 C10 1 2 3