TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11304 T5-5-82 Fault Code Trouble Cause Influenced Control 11304-3 Abnormal Travel Pilot Pres- sure Sensor High Voltage Voltage: 4.75 V or higher • Auto-Idle Control • Idle Speed-Up Control • ECO Control • Travel HP Mode Control • Travel Torque-Up Control • Pump 1 Flow Rate Limit Control • Pump 1 Flow Rate Control Valve at Travel (ZX160-3 Class Only) • Pump 2 Flow Rate Limit Control • Pump 2 Flow Rate Control Valve at Travel (ZX160-3 Class Only) • Travel Motor Swash Angle Control • Attachment Flow Rate Control • Travel Alarm Control 11304-4 Abnormal Travel Pilot Pres- sure Sensor Low Voltage Voltage:
Less than 0.25 V • Auto-Idle Control • Idle Speed-Up Control • ECO Control • Travel HP Mode Control • Travel Torque-Up Control • Pump 1 Flow Rate Limit Control • Pump Flow Rate Control Valve at Travel (ZX160-3 Class Only) • Pump 2 Flow Rate Limit Control • Pump Flow Rate Control Valve at Travel (ZX160-3 Class Only) • Travel Motor Swash Angle Control • Attachment Flow Rate Control • Travel Alarm Control