TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11404 Connector (Harness end of connector viewed from the open side) valve unit (SG) (relief pressure control). · Between terminal #A17 of connector MC-A in MC and terminal #2 of connector in solenoid valve unit (SG) (relief pressure control). MC Connector MC-A T183-05-04-008 Solenoid Valve Unit (SG) (Relief Pressure Control) T1V1-05-04-003 T5-5-89 Fault Code Trouble Cause Influenced Control 11404-2 Abnormal Current Feedback of Solenoid Valve Unit (SG) (Re- lief Pressure Control) Current:
Both of Higher than 920 mA or Less than 60 mA • Power Digging Control • Auto-Power Lift Control • Travel Pressure Increasing Control 11404-3 Abnormal Feedback High Current of Solenoid Valve Unit (SG) (Relief Pressure Control) Current: Higher than 920 mA • Power Digging Control • Auto-Power Lift Control • Travel Pressure Increasing Control 11404-4 Abnormal Feedback Low Current of Solenoid Valve Unit (SG) (Relief Pressure Control) Current: Less than 56 mA • Power Digging Control • Auto-Power Lift Control • Travel Pressure Increasing Control Switch connectors of Faulty solenoid valve unit YES solenoid valve unit (SG) (SG) (relief pressure con- (relief pressure control) trol).
YES and other solenoid valve unit (SF, SC or SI). Check if fault code in Faulty MC. switched solenoid valve NO Check for continuity in unit is displayed. harness between MC and solenoid valve unit (SG) (relief pressure control). · Between terminal #A11 of connector MC-A in Open circuit in harness. MC and terminal #1 of NO connector in solenoid Faulty solenoid valve unit (SG) (relief pressure con- trol). Open circuit in harness. NO #A17 #A11