hitachi — Fuse Inspection

TROUBLESHOOTING / Electrical System Inspection FUSE INSPECTION Cracks in a fuse are so fine that it is very difficult or impossible to find by visual inspection. Use a tester in order to correctly inspect fuse continuity by following the instructions described below. 1. Turn the key switch ON. When the key switch is turned ON, current from key switch terminal M activates the battery relay so that electric power is supplied to all circuits except the glow plug relay circuit. (Refer to the circuit diagram.) 2. Remove the fuse box cover. Set the tester. (Measurement Range: 0 to 30 V) 3. Ground the negative probe of tester to the vehicle frame.

Touch the terminals located away from center of the fuse box with the positive probe of tester one at a time. When normal continuity of a fuse is intact, the tester will indicate 20 to 25 V (battery voltage). NOTE: All terminals located along the lengthwise centerline of the fuse box are connected to the power source, while terminals located away from center of the fuse box are con- nected to loads (accessories). Therefore, test all fuses in the same method except for the glow relay circuit fuse. Check the glow relay circuit fuse with the key switch turned to the ON position and follow the procedure in step 3. 10 20 9 19 8 18 7 17 6 16 5 15 4 3 14 13 2 12 1 11 M178-07-034 T5-7-4 Fuse No.

Capacity Connected to Fuse No. Capacity Connected to 1 20 A Work Light Relays 1 and 2 11 10 A Horn Relay 2 10 A Wiper Relay, Wiper Motor, Washer Relay 12 5 A Radio, Cab Light 3 20 A Heater (Air Conditioner Unit) 13 10 A Cigarette Lighter 4 10 A MC (Solenoid Valve Power) 14 5 A Fuel Pump 5 5 A Optional 1 15 10 A Auxiliary 6 10 A Optional 2 16 5 A Glow Relay 7 10 A Empty 17 5 A Air Conditioner Unit 8 30 A ECM Main Relay 18 5 A MC, ECM, ICF, Monitor Unit (Power ON Signal) 9 10 A Security Horn, Security Horn Relay (Power), Radio (Backup) 19 5 A Monitor Unit (Main Power) 10 5 A MC, ICF (Main Power) 20 5 A Optional 3