STARTER N Service procedure G Inspection after reassembly After reassembly, check the starter by supplying current. CAUTION When current is supplied to the starter, the pinion 3 will spring out and rotate. Be careful not to touch it by hand. The magnet switch 5 may be very hot after the end of inspection. Be careful when you touch it. The time during which current is supplied to the starter should be limited to 10 seconds or less on the pull-in coil P side and 30 seconds or less on the holding coil H side. If current is supplied to the coils for a longer period, the coils will be overheated and baked. When current is supplied to the starter, a large current that exceeds 100A will flow.
When the starter is inspected, therefore, use thick cables like booster cables. Check to ensure that all the connections are tight and secure. 14266 14257 (1) Performance test Wire the starter as shown. A: Ammeter B: Starter terminal B C: Switch D: DC power supply S: Starter terminal S V: Voltmeter Set the voltage at 23V DC. 10767 CAUTION The voltage that is applied should be limited to 24V maximum. The following operations are performed by supplying current to the starter. It is therefore necessary that the series of operations ranging from measuring the current that flows through the starter to measuring the rotating speed are completed in less than 30 seconds.
Set the switch C to ON to supply current to the starter. At the time, the pinion 3 will spring out and rotate. CAUTION When the switch C is set to ON, current is supplied to both the pull-in coil P and holding coil H. When the large current from the DC power supply D is supplied from terminal B of the starter to terminal M, the current to the pull-in coil is interrupted, and current flows to the holding coil only. To prevent baking the holding coil, therefore, all the operations must be completed in less than 30 seconds. 14258 Measure the current and rotating speed of the starter. Measure the rotating speed of the starter by illuminating the pinion 3 with a stroboscope.
Set the switch C to OFF to stop supplying current to the starter. If the reading is out of the standard value, disassemble and check the starter. 54-34