7 Load handling – 7.2.3 Pressure reducer 9 7.2.3 Pressure reducer page Pressure reducer, checking servo pressure WARNING Hot, pressurized oil. Personal injury, burn injury, rash or irritation. Always depressurize the hydraulic systems before starting to work on the hydraulic systems. Avoid skin contact with the oil, use protective gloves. 1 Operate and warm up the machine so that the hydraulic oil reaches operating temperature, at least 50 ° C. 2 Machine in service position, see section B Safety . 3 Depressurize the hydraulic systems, see section B Safety . 4 Turn the start key to position 0. 5 Connect a pressure gauge (0–25 MPa) to the test outlet on the pressure reducer.
6 Start the engine and check the servo pressure. Compare with pressure plate. MPa Turn the steering wheel or activate a load handling function to activate the hydraulic oil pumps. The servo pressure is higher than the stand-by pressure of the hydraulic oil pumps. 7 Depressurize the hydraulic and brake systems, see section B Safety , Hydraulic and brake systems, depressurizing . MPa MPa MPa MPa MPa MPa 8 Remove the pressure gauge and fit the protective cap on the pressure check connection. MPa MPa MPa 001029 920643.0024 UDRF01.04GB Maintenance manual DRF 400–450