6 0 Complete machine – Complete machine 5 Use the function group to find more information if needed. In section 0–12 there is function description, the function's in- cluded components and their position as well as, in certain cas- es, work instructions for how components are checked, cleaned or adjusted. 6 If possible eliminate component fault by testing the component individually. Electric components can sometimes be checked with resist- ance measurements using a multimeter. Hydraulic components are often checked by measuring pres- sure (then described in the function group and indicated in the section C Preventive maintenance ).
Sometimes valves can be activated mechanically to determine if the malfunction is elec- tric or hydraulic. 7 If the component's measuring values are correct, continue by troubleshooting electric cabling and hydraulic hoses. For electric cabling, see Troubleshooting cable harness page 7 . For hydraulic hoses, see Troubleshooting hydraulic hoses page 8 . 8 If the cable is not defective then connect the lead to the control unit. NOTE The main electric power shall be turned off with the bat- tery disconnector! 9 Disconnect the cable harness from the component in question. 10 Turn on the main electric power with the battery disconnector. 11 Turn the ignition key to the operating position.
12 Check that voltage reaches the component. Table 1. Example of error code information in error code list UDRF01.04GB Maintenance manual DRF 400–450 Cod e Description Limit Action Connec- tion and compo- nent Diagnos- tic menu Function group 34 Signal error from switch parking brake, indicates re- leased and applied at same time or nothing at all. Parking brake cannot be re- leased. Use diagnostic menu to check cable between control unit and compo- nent. Check component. D791-1/K8:5 - S107, K8:13 - S107 HYD, menu 5 4.1.2 Parking brake control