0 Complete machine – Complete machine 7 page Troubleshooting cable harness NOTE Perform troubleshooting for all cables in the same way to avoid damage to control units, components or measuring equipment. 1 Study the circuit diagram in question, check where the suspect- ed cable is connected and if, and if so where, it is spliced. 2 Turn off the main electric power with the battery disconnector. 3 Unplug the connector at the control unit or component in ques- tion. 4 Check if there is open circuit. NOTE Some components cannot be checked without power sup- ply to the component. In such an event, proceed to point 5. a.
Measure resistance between connections for the compo- nent in the connector at the control unit or component. b. The resistance must correspond with the component. Oth- erwise there may be an open circuit or short circuit in cable harness and/or component. 5 Check if there is short circuit to frame: a. Unplug the connector both at the control unit and compo- nent in question. b. Measure the resistance of one lead at a time. Measure be- tween the lead and a frame-connected part of the ma- chine. c. The multimeter should show endless resistance. UDRF01.04GB Maintenance manual DRF 400–450