12 2 Transmission – 2.8 Control system transmission page Transmission, calibrating DANGER Do not leave the machine during calibration. The machine may start to move. 1 Park the machine on level ground, engage neutral position and apply the parking brake. Run the engine at idling speed. 2 To select the function to calibrate, first navigate to the service menu. Then press Enter. 3 Enter code for calibration. The code is obtained via Kalmar Industries Support. NOTE The code determines which service menu shall be activat- ed (Diagnostics, Initiation or Calibration). 4 Select group by scrolling with the arrow keys (1 and 2) and con- firm DRIVE-TRAIN with Enter.

5 Scroll with the arrow keys (1 and 2) and select DRIVE-TRAIN, menu 4. 6 Check that the oil temperature is 61 ° C. If the oil temperature is too low go to DRIVE-TRAIN, menu 4. A. Apply the footbrake so that the machine is stationary. B. Select travel direction forward and apply maximum accel- eration for 20 seconds. C. Engage neutral position and apply maximum acceleration for 10 seconds, run the engine at idling speed. D. Repeat steps B and C until the oil is hot. The engine speed may be reduced towards the end of heating because the oil from the gearbox is too hot. If this occurs, main- tain neutral position and maintain an engine speed of 1200 rpm for 20 seconds.

When the temperature is correct, MODE is changed from 0 to 1. UDRF01.04GB Maintenance manual DRF 400–450 000056 1 2 3 4 5 000060 1 2 3 CALIBRATION 000062 SCALE STEERING DRIVE-TRAIN RETURN 000082 CALIBR DRIVE-TRN 4(4) GEARBOX WARM UP MODE X ACTUAL TEMP XXX TARGET TEMP XXX