PIPER COMANCHE SERVICE MA~t'AL FIGl'R[ 7A·l!\. LEAD POSITIOl'lING FIGt:RE 7A·16. IMPl:LSE COl'Pll~G ~OTE The magneto sen ice instructions in this manual are to cover minor repairs and timing. For further repairs and adjustments of the magnetos, it is recommended that the manufacturer's service instruction" be followed. 7A·70. Removal Of Magneto. a. Lift the side panels of the engine cowling. b. Disconnect the "P" lead from the magneto and the retard breaker lead from the left. series. magneto. c. d. Remme the harness outlet plate from the magneto by removing the four attaching screws. Remove the two nuts and washers securing the magneto to the engine accessory housing.
Pull the magneto from the engine. e. 7 A- i I. Timing Procedure, (Internal Timing) -20 and -200 series Magneto Main Breaker Points. When installing new or adjusting breaker points and before timing the magneto to the engine. it is important that the internal timing of the magneto be correct. a, To internally time the magneto it should be removed from the engine to determine "E" gap. h. To determine "E" gap. find neutral position of the magneto drive by rotating drive coupling in a timing inspection hole. At the same location. the drive should feel to have fallen into a notch or neutral position. ISSl'ED: 8/18/72 2D20 POWER PL.\. l..EF'T FlOTATION MEA5iJRE 3COv THICKNESS "~1"E