PIPER COMANCHE SERVICE MANUAL FIGURE 9·29b. TURNING STARTING MOTOR COMMUTATOR PIGURE 9·29c. TESTING MOTOR ARMATURE FOR SHORTS 9-83. Fi.ld Coils. a. ~eck the field coils for groWlds (Refer to Fipr~ 9-29d) by placing cae test probe 01'1 the fraIDe and the other on the starter tenDieal. Be sure the brushes are nex accidentally touching the frame. If the lamp U&hts, the fields are &rOUilded. Repair or replace. b. Inspect all ccanections to make sure they are dean and ti&ht and iespect insulation for deted oration. 9-84. Brush Hold.". a. To test brush holders, touch one test probe to the brush plate and the other to each brush holder. b.

The test lamp should Uiht _Ium the Itouftded brush holders are touched and should not light when the insulated brush holders ate touched. 9-85. And PiniOft H_lin,. Icspect housU1gS for cracks and bearings for excessive wear. Remove rust, paint or grease from mountinl surfaces. 9-86. B.ndix Drive. The Bendix Drive should be wiped clean with a dry cloth. The pmllJl'l should tum smoothly in one directioo and should lock in the other direction. Replace drive if it fails to check as above or if the PWOIl teeth are excessively wom or damaled. 9-87. A ..... Dly. a. When a.sembling the startina motor.

always uae all arbor press and the proper beariac arbor for insta1linl If8phitized bronze and roller bearil1ls. The Bendix shaft should have a thin film of Lubriplate :77i or equiva- lent on the Bendix portion of the shaft. End FIGURE 9·29d. TESTING MOTOR FIELDS FOR GROUNDS ELECTRICAL SYSTFlIt ISSUED: 8/18/72 3 C17