Komatsu — BLEEDING AIR FROM FUEL CIRCUIT

TESTING AND ADJUSTING BLEEDING AIR FROM FUEL CIRCUIT 2. Remove air bleed plug (2) of the fuel filter and operate priming pump (4). a Continue operating the priming pump until flow out from the plug hole. When fuel comes out, install the plug. Air bleeding steps i) Remove air bleeding plug (2) of fuel filter (1) and operate priming pump (4). Continue to operate the priming pump until fuel is confirmed to flow out of the air bleed- ing plug hole and then tighten it. Air bleed plug: 7.8 – 9.8 Nm {0.8 – 1.0Nm} Air bleeding plug: 7.8 – 9.8 Nm {0.8 – 1.0 kgm} 3.

There are the following two cases that the engine does not start up easily after bleeding air from CRI, (Common Rail Injection System), i.e. even after carrying out the Items 1 and 2 above. a If air has not been removed completely, leav- ing some in the system, cranking up the engine with the engine starting motor cannot get rid of the remaining air in a short span of time. Thus the engine start-up becomes diffi- cult. 1) In the cases that the fuel has run out, that the fuel filter has been replaced or that some fuel device has been removed and installed.

Most of the fuel is left in the fuel circuit, so the engine may be started after bleed- ing air with the air bleeding methods introduced in the Item 1 and 2 above. 2) In the case that a number of fuel devices have been removed and installed in course of engine overhauling. Little fuel is left in the fuel circuit, so air cannot be get rid of completely with the air bleeding methods introduced in the Item 1 and 2 above (i.e. ordinary method). In that case, bleed air in the fol- lowing manner. ii) Remove fuel pressure measuring plug (3) for the fuel filter and operate priming pump (4).

Continue to operate the priming pump until fuel is confirmed to flow out of the air bleed- ing plug hole and then tighten it. Fuel pressure measuring plug: 3.9 – 6.9 Nm {0.4 – 0.7 kgm} iii) Loosen air bleeder (5) of the fuel supply pump (only after loosening the lock nut) and operate priming (4) 90 to 100 times. Continue to operate the priming pump until fuel is confirmed to flow out of air bleeder (5) and then tighten it. Air bleeder: 4.9 – 6.9 Nm {0.5 – 0.7 kgm} Still continue to operate the priming pump until it becomes harder to operate and a relief sound of overflow valve (6) in the fuel supply pump is heard. (A high pitch sound) it requires approx.

50 times of operation to reach that stage. iv) Push in the knob of priming pump (4) to tighten it. v) Crank up the engine with the engine starting motor for start-up. a Do not keep the engine starting motor run- ning idly for more than 20 seconds. More- over try to start up the engine only after two minute pause. a If the engine does not start up even after repeating to crank for 20 seconds 4 times, insufficient air bleeding is suspected of. In that case, start the air bleeding steps once again from the beginning. 20-122 D85EX-15 (1)