TESTING AND ADJUSTING TESTING CONTROL CIRCUIT MAIN PRESSURE TESTING CONTROL CIRCUIT MAIN PRESSURE a Testing and adjusting instruments for control cir- cuit main pressure a The control circuit main pressure is the pressure lowered by the self-pressure reducing valve. It is used commonly for ripper PPC, blade PPC, fan pump control and steering EPC. 5. Run the engine at high idling and set the blade lever and ripper lever in neutral and measure the oil pressure. Measuring Stop the machine on a level place, lower the work equipment to the ground, and set the parking brake lever and safety lock lever in the LOCK position. a Measure the control circuit main pressure under the following condition.
Hydraulic oil temperature: Within operating range 1. Remove the main control valve cover. 2. Disconnect hose (1). 6. After finishing measurement, remove the mea- suring instrument and return the removed parts. Adjusting a The self-pressure reducing valve cannot be adjusted. 3. Install oil pressure pickup adapter J2 and con- nect the disconnected hose again. 4. Install nipple [1] of hydraulic tester J1 and con- nect oil pressure gauge [2]. a Use an oil pressure gauge of 5.9 MPa {60 kg/cm 2 }. D85EX-15 20-147 (1) Symbol Part No. Name J 1 799-101-5002 Hydraulic tester 790-261-1203 Digital hydraulic tester 2 799-401-3200 Oil pressure pickup adapter (Size 03) 12896-11009 O-ring