Komatsu — ERROR CODE [15SEL1] (1ST CLUTCH:SEE THE LIST.(L1))

TROUBLESHOOTING ERROR CODE 15SEL1 ERROR CODE 15SEL1 (1ST CLUTCH: SEE THE LIST. (L1)) Circuit diagram related to transmission level 1 clutch ECMV 20-412 D85EX-15 (1) Action cod e Error code Controller code Trouble 1st clutch: See the list. (L1) (Steering and transmission controller system) CALL E03 15SEL1 Steering and transmission Contents o trouble f • The fill switch signal is not set off at output stop of the transmission level 1 clutch solenoid circuit. Action of controller • Flashes caution lamp and turns on caution buzzer. • Limits operation of engine and transmission. Problem th appears o machine at • Once machine is stopped, engine speed is limited to medium (half).

n • Once machine is stopped, running is limited to F1 and R1. Related informatio • The input state (ON/OFF) from the level 1 clutch fill switch can be checked in monitoring mode. (Code 31520: Transmission fill switch input state) n • Method of reproducing error code:

Engine start + Forward running Possible caus and standard value in norm state Cause Defective 1st clutch fill 1 switch (Internal short) Defective harness ground- es 2 ing (Contact with ground cir- cuit) al Defective steering and 3 transmission controller Defective hydraulic pres- 4 sure system Standard value in normal state/Remarks on troubleshooting Defective 1st clutch fill switch (Internal short) aPrepare with starting switch OFF, then start the engine for trouble- shooting. F1T (male) PCCS lever Resistance Between (1) – chassis ground Other than F1/R1 Min. 1Mz F1·R1 Max.

1z Defective harness ground- ing (Contact with ground cir- cuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between STC3 (female) (19) – F1T (female) (1) with chassis ground Resistance Max. 1Mz Defective steering and transmission controller aPrepare with starting switch OFF, then start the engine for trouble- shooting. STC3 PCCS lever Voltage Between (19) – chassis ground Other than F1/R1 20 – 30V F1·R1 Max. 1V Defective hydraulic pres- sure system When no fault is detected in the electric system, the hydraulic pressure system is assumed to be abnormal. Carry out the related troubleshoot- ing (H mode).