TROUBLESHOOTING ERROR CODE DK55KX, ERROR CODE DK55KZ ERROR CODE DK55KX (FORWARD-REVERSE POTENTIOMETER: INPUT SIGNAL IS OUT OF NORMAL RANGE (KX)) ERROR CODE DK55KZ (FORWARD-REVERSE POTENTIOMETER: DISCONNECTION OR SHORT CIRCUIT (KZ)) D85EX-15 20-519 (1) Action code Error code Controller code Trouble Forward-reverse potentiometer: Input signal is out of normal range (KX) (Steering and transmission controller system) CALL E04 DK55KX Steering and transmission Contents of trouble • Either of error codes [DK56KA] and [DK56KB] of forward-reverse potentiometer systems 1 and 2 and either of error codes [DK57KA] and [DK57KB] are displayed simultaneously.
Action of controller • Flashes caution lamp and turns on caution buzzer. • Limits operation of engine, transmission, and brake. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, it cannot travel any more. Related information • Input (Voltage) from forward-reverse potentiometers can be checked in monitoring mode. (Code 50200: Voltage of forward-reverse potentiometer 1) (Code 50201: Voltage of forward-reverse potentiometer 2) • Method of reproducing error code: Turn starting switch ON and operate PCCS lever (for forward/re- verse travel).
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Carry out troubleshooting for error codes [DK56KA], [DK56KB], [DK57KA], and [DK57KB]. Action code Error code Controller code Trouble Forward-reverse potentiometer: Disconnection or short circuit (KZ)) (Steering and transmission controller system) CALL E04 DK55KZ Steering and transmission Contents of trouble • When starting switch is turned ON, either of forward-reverse potentiometer systems 1 and 2 is abnor- mal, then either of error codes [DK56KA] and [DK56KB] and either of error codes [DK57KA] and [DK57KB] are displayed simultaneously.
Action of controller • Flashes caution lamp and turns on caution buzzer. • Limits operation of engine, transmission, and brake. Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Input (Voltage) from forward-reverse potentiometers can be checked in monitoring mode. (Code 50200: Voltage of forward-reverse potentiometer 1) (Code 50201: Voltage of forward-reverse potentiometer 2) Related information • Method of reproducing error code: Turn starting switch ON and operate PCCS lever (for forward/re- verse travel).
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Carry out troubleshooting for error codes [DK56KA], [DK56KB], [DK57KA], and [DK57KB].