TROUBLESHOOTING ERROR CODE DK55L8 ERROR CODE DK55L8 (FORWARD-REVERSE POTENTIOMETER: SEE TABLE (L8)) 20-520 D85EX-15 (1) Action code Error code Controller code Trouble Forward-reverse potentiometer: See table (L8) (Steering and transmission controller system) CALL E03 DK55L8 Steering and transmission Contents of trouble • Total signal voltage of each of forward-reverse potentiometer 1 system and 2 system is below 4.41V or above 5.59V. Action of controller • Flashes caution lamp and turns on caution buzzer. • Continues controlling with signal of normal one of forward-reverse potentiometer 1 system and 2. • Limits operation of engine and transmission.
Problem that appears on machine • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, travel is limited to F1 and R1. Related information • Input (Voltage) from forward-reverse potentiometers can be checked in monitoring mode. (Code 50200: Voltage of forward-reverse potentiometer 1) (Code 50201: Voltage of forward-reverse potentiometer 2) • Method of reproducing error code: Turn starting switch ON and operate PCCS lever (for forward/re- verse travel). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting Carry out troubleshooting for error codes [DK56KA], [DK56KB], [DK57KA], and [DK57KB].