Komatsu — ERROR CODE [DW7BKB] (FAN REVERSE SOLENOID : SHORT CIRCUIT (KB))

TROUBLESHOOTING ERROR CODE DW7BKB ERROR CODE DW7BKB (FAN REVERSE SOLENOID: SHORT CIRCUIT (KB)) Circuit diagram related to fan reverse solenoid D85EX-15 20-535 (1) Action cod e Error code C ontroller code Trouble Fan reverse solenoid: Short circuit (KB) (Steering and transmission controller system) E01 DW7BKB Steering and transmission Contents o trouble f • When signal was output to fan reverse solenoid circuit, abnormal current flowed. Action of controller • Stops outputting to fan reverse solenoid circuit. Problem tha appears on machine t • The fan reversing function cannot be used. Related information • Output (Current) to fan reverse solenoid can be checked in monitoring mode.

(Code 40909: Cooling fan reverse solenoid output current) • Method of reproducing service code: Turn starting switch ON and operate fan in reverse. Possible caus and standard value in norm state Cause Defective fan reverse sole- 1 noid (Internal short circuit) Short circuit with chassis 2 ground in wiring harness es (Contact with ground circuit) al Short circuit in wiring har- 3 ness (with another wiring harness) Defective steering and 4 transmission controller Standard value in normal state/Remarks on troubleshooting fan reverse sole- rnal short circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

FARC (male) Resistance Between (1) – (2) 34 – 44z Between (1) – chassis ground Min. 1Mz uit with chassis wiring harness with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit of wiring harness between STC3 (female) (18) – FAR2 (female) (1) with chassis ground Resistance Min. 1Mz uit in wiring har- another wiring aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Short circuit in wiring harness between STC3 (female) (18) – FAR2 (female) (1) with wiring harness between STC3 (female) (13) – FAR2 (female) (2) Resistance Min.

1Mz steering and ion controller aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC3 Resistance Between (18) – (13) 34 – 44z Between (18) – chassis ground Min. 1Mz