Komatsu — E-26 THE AIR CONDITIONER DOES NOT OPERATE

TROUBLESHOOTING E-26 E-26 THE AIR CONDITIONER DOES NOT OPERATE. 20-656 D85EX-15 (1) Trouble (1) • No air flow Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective circuit breaker (CB2) When the circuit breaker is cut off, a ground fault may have possibly occurred in the circuit. 2 Defective blower main relay (coil side) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON.

CN-R1 (male) Resistance Between (1) and (2) 240 ± 40z 3 Defective blower main relay (contact side) aPrepare with the starting switch OFF, then turn the starting switch ON and carry out troubleshooting. CN-R1 Voltage Between (8C) and ground 20 – 30V 4 Defective blower Hi relay (coil side) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. CN-R2 (male) Resistance Between (1) and (2) 240 ± 40z 5 Defective blower Hi relay (contact side) aPrepare with the starting switch OFF, then turn the starting switch ON and carry out troubleshooting.

The relay is in order when the motor rotates after the starting switch is turned ON and the blower Hi switch is turned on. 6 Defective blower Mi1 relay (coil side) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. CN-R3 (male) Resistance Between (1) and (2) 240 ± 40z 7 Defective blower Mi1 relay (contact side) aPrepare with the starting switch OFF, then turn the starting switch ON and carry out troubleshooting. The relay is in order when the motor rotates after the starting switch is turned ON and the blower Mi switch is turned on.

6 Defective blower Mi2 relay (coil side) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. CN-R4 (male) Resistance Between (1) and (2) 240 ± 40z 7 Defective blower Mi2 relay (contact side) aPrepare with the starting switch OFF, then turn the starting switch ON and carry out troubleshooting. The relay is in order when the motor rotates after the starting switch is turned ON and the blower Mi switch is turned on. 8 Defective blower motor aPrepare with the starting switch OFF, then turn the starting switch ON and carry out troubleshooting.

The motor is in order when it rotates after the starting switch is turned ON and the blower Lo switch is turned on. 8 Defective blower motor aPrepare with the starting switch OFF, then turn the starting switch ON and carry out troubleshooting. The motor is in order when it rotates after the starting switch is turned ON and the blower Lo switch is turned on.