TROUBLESHOOTING E-26 D85EX-15 20-657 (1) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 9 Disconnection of wiring har- ness (Disconnection in wir- ing or defective contact in connector) aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. Wiring harness between CN-R4 (female) (14C), AC1 (female) (14A), CN-R (female) (0D) or CN-R2 (female) (14E) or CN-R3 (female) (14N) and ground Resistance Max. 1z Wiring harness between CN-B(female) (11B) and CN-R1 (female) (11A) Resistance Max.
1z Wiring harness between CN-B (female) (12A) and CN-R2 (female) (12B) or CN-R (female) (11C) Resistance Max. 1z Wiring harness between CB2 outlet and AC1 (female) (1A), CN-R1 (female) (1D), CN-R2 (fe- male) (1E) or CN-R4 (female) (11H) Resistance Max. 1z Wiring harness between CN-R1 (female) (2B) and AC1 (female) (2A) Resistance Max. 1z aPrepare with the starting switch OFF, then carry out troubleshooting without turning the starting switch ON. Wiring harness between CN-R3 (female) (3B) and AC1 (female) (3B) Resistance Max. 1z Wiring harness between CN-R2 (female) (5B) and AC1 (female) (5A) Resistance Max. 1z Wiring harness between CN-R4 (female) (4B) and AC1 (female) (4A) Resistance Max.
1z 10 Defective control panel When Causes 1 to 9 are not applicable, the control panel is supposed to be defective. 11 Different failure phenome- non When any cause cannot be specified, failure phenomenon may have been mistaken. Carry out the troubleshooting of “Cooling is not possi- ble.”