Komatsu — H-11 ALL WORK EQUIPMENT SPEEDS ARE SLOW

TROUBLESHOOTING H-10, H-11 H-10 ABNORMAL SOUND COMES OUT FROM AROUND HSS AND WORK EQUIPMENT PUMP OR HSS MOTOR H-11 ALL WORK EQUIPMENT SPEEDS ARE SLOW 20-710 D85EX-15 (1) Trouble • Abnormal noise from around HSS and work equipment pump. Related information • Confirm that the oil quantity of the hydraulic oil tank is normal before troubleshooting. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Inappropriate oil The oil used is assumed to be inappropriate; directly check it. 2 Clogged hydraulic oil tank strainer The strainer of the hydraulic oil tank is assumed to be clogged; directly check it.

3 Air inhaled in suction circuit Air is assumed to be inhaled in the suction circuit of the HSS and work equipment pump; directly check the pipes. 4 Internally defective HSS pump The HSS and work equipment pump is assumed to be defective inter- nally; directly check it. 5 Internally defective HSS motor The HSS motor is assumed to be defective internally; directly check it. Trouble • All work equipment speeds are slow. Related information • Confirm that the oil quantity of the hydraulic oil tank is normal before troubleshooting.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective PTO (pump drive unit of HSS and work equip- ment) The PTO pump drive unit of the work equipment is assumed to be de- fective; directly check it. 2 Defective HSS and work equipment pump The pump of the HSS and work equipment is assumed to be defective; directly check it. 3 Defective unload valve function aPrepare with starting switch OFF, then drive the engine in high idling mode for troubleshooting.

Work equipment lever Unload pressure Full neutral 2.45 – 3.82MPa {25 – 39kg/cm2} 4 Defective set pressure or defective function of main relief valve aPrepare with starting switch OFF, then drive the engine in high idling mode for troubleshooting. Work equipment lever Main relief pressure Stroke end 22.54 ± 1.18MPa {230 ± 12kg/cm2} 5 Defective function of self- pressure reducing valve (PPC original pressure) aPrepare with starting switch OFF, then drive the engine in high idling mode for troubleshooting.

Work equipment lever Original pressure of control circuit Full neutral 3.77 – 4.46MPa {38.5 – 45.5kg/cm2} 6 Internally defective PPC valve When the troubleshooting in cause 5 is abnormal, the PPC valve is as- sumed to be defective internally; directly check it.